Activ Ankle
.

Solutions for the fixation of ankle fractures.

The implants in the Activ Ankle range are designed for the fixation of fractures, osteotomies and pseudarthrosis of the distal and diaphyseal fibula, the distal tibia and the fixation of the syndesmosis in adults.

Activ Ankle is the solution for treating trauma to the internal and external malleolus as well as for diaphyseal fractures of the fibula. Thanks to their design and ease of bending, the plates can respond to a wide spectrum of fractures while allowing, in certain cases, early mobilization of the operated ankle.

Complete treatment of malleolar fractures.

STANDARD LATERAL PLATES

Activ Ankle offers 5 sizes of standard plates for the distal fibula, usable via a lateral approach.

 

These implants can, if needed, accommodate a syndesmosis screw.

 

Their distal screws are lockable, polyaxial and Ø2.8 mm, while their proximal screws are Ø3.5 mm, locking or non-locking.

 

Bending areas also facilitate the congruence of the plate to the bone, in particular on the diaphyseal part, which presents great anatomical variability from one patient to another.

NARROW LATERAL PLATES

Activ Ankle also offers 2 sizes of narrow lateral plates for distal fibula fractures, designed for use via a lateral approach and capable of accommodating a syndesmosis screw if needed.

 

Their distal screws are lockable, polyaxial and Ø2.8 mm, while their proximal screws are Ø3.5 mm, locking or non-locking.

 

Bending areas facilitate the congruence of the plate to the bone, in particular on the diaphyseal part, which presents great anatomical variability from one patient to another.

 

POSTEROLATERAL PLATES

Activ Ankle also offers 3 sizes of plates for treating distal fibula fractures via a posterolateral approach.

 

Their distal screws are lockable, polyaxial and Ø2.8 mm, while their proximal screws are Ø3.5 mm, locking or non-locking.

DIAPHYSEAL PLATES

It accepts Ø3.5 mm locking and non-locking screws.

MEDIAL MALLEOLUS PLATES

The range of Activ Ankle plates for the fixation of low fractures of the medial malleolus includes two standard plates and one epiphyseal hook plate, meeting the different surgical philosophies and anatomical constraints of the area to be treated. They accept Ø2.8 mm locking screws.

 

The plates and instruments for Activ Ankle Medial Malleolus are not included in the main Activ Ankle kit. Please refer to the kit composition: Activ Ankle Medial Malleolus.

FIXATION BY SCREW

Preliminary reduction of the fracture, as well as fixation of the medial malleolus, can be achieved using an osteosynthesis screw.

Ø3.5 mm cortical screws, Ø4.0 mm cannulated screws or even Ø4.0 mm lag screws are included in the kit.

 

Key features of the Activ Ankle range.

  • A range of plates for three surgical approaches
  • Angular freedom of 20° to ensure locked polyaxial fixation of distal screws
  • Ø3.5 mm cortical screw or Ø4.0 mm lag screw, available for fixation of the syndesmosis
  • Implants available in sterile or non-sterile versions or in a single-use kit (Initial A)

Our INITIAL solution for the ankle.

Certains produits ne sont pas disponibles sur tous les marchés. Pour vous permettre une navigation optimale merci de renseigner le pays où vous exercez.

Le site délivre des informations destinées uniquement à l’usage des professionnels de la santé. En cliquant sur Oui, vous confirmez que vous êtes professionnel de santé.
Ces informations ont pour intérêt de présenter la gamme de dispositifs médicaux de Newclip Technics. Ces produits doivent être manipulés et/ou implantés par des personnes formées, qualifiées et ayant pris connaissance de la notice d’utilisation. Le chirurgien reste responsable de son propre jugement professionnel et clinique avant toute utilisation de produits spécifiques sur un patient donné.