INITIAL F
.

Your single-use solution for Lapidus and MTP arthrodesis plates.

The INITIAL F range consists of sterile single-use solutions dedicated to forefoot arthrodesis, in particular of the first metatarsophalangeal (MTP) joint and the Lapidus procedure.

In these indications, Lapidus arthrodesis is a widely recognized surgical procedure for the treatment of moderate to severe hallux valgus, particularly in cases of first ray hypermobility1, and is increasingly performed worldwide for recurrent or unstable deformities. Arthrodesis of the first metatarsophalangeal (MTP) joint is considered the gold standard treatment for advanced stages of hallux rigidus, the most common form of foot osteoarthritis3.

In this context, Newclip Technics has developed single-use kits designed to address the challenges of standardization, logistical simplification, and infection risk control, while providing everything necessary for the proper execution of the surgical procedure.

Each kit includes one plate size, its screws, and the associated instrumentation in a sterile ready-to-use format. It enables surgeons and healthcare staff to reduce preparation time and contributes to improved operating room organization.

The implants of the INITIAL F range are dedicated to arthrodesis procedures, fracture and osteotomy fixation, and revision foot surgery in adults.

Ready when you are!

Donantoni M, Santini S, Martinelli D, Marinozzi A. Surgical Techniques for Lapidus Arthrodesis: Approaches, Indications, and Outcomes. J Clin Med. 2025 Jun 28;14(13):4591. doi: 10.3390/jcm14134591. PMID: 40648964; PMCID: PMC12249525.

Thompson IM, Bohay DR, Anderson JG. Fusion rate of first tarsometatarsal arthrodesis in the modified Lapidus procedure and flatfoot reconstruction. Foot Ankle Int. 2005 Sep;26(9):698-703.

Patel J, Swords M. Hallux Rigidus. 2023 Nov 22. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan–. PMID: 32310479.

Our sterile solution: INITIAL F – Lapidus.

Lapidus arthrodesis is a widely recognized surgical procedure for the treatment of moderate to severe hallux valgus, particularly in cases of first ray hypermobility1. It is now increasingly performed worldwide and recommended for recurrent or unstable deformities2. In this context, INITIAL F – Lapidus is a single-use solution designed to meet operating room requirements and support surgeons in this procedure, which is essential for restoring weight-bearing and ensuring patient satisfaction.

Donantoni M, Santini S, Martinelli D, Marinozzi A. Surgical Techniques for Lapidus Arthrodesis: Approaches, Indications, and Outcomes. J Clin Med. 2025 Jun 28;14(13):4591. doi: 10.3390/jcm14134591. PMID: 40648964; PMCID: PMC12249525.
Thompson IM, Bohay DR, Anderson JG. Fusion rate of first tarsometatarsal arthrodesis in the modified Lapidus procedure and flatfoot reconstruction. Foot Ankle Int. 2005 Sep;26(9):698-703.

INITIAL F – Lapidus KIT

The INITIAL F – Lapidus kits consist of two blisters:

  • The first is used for the implantation of the plate and associated screws. It includes the plate, screws (locked and non-locked), pins, T8 quick-release screwdriver, length gauge, quick-release drill, threaded guide gauge, handle for guide gauge, as well as pins of different lengths and diameters.
  • It is also possible to place a Ø4.0 mm head compression screw in addition to the plate, which is why the kit includes a second blister with the necessary instrumentation for proper implantation of this screw. This blister contains an AO quick-release drill, pins, a 2-in-1 instrument, and a differential pin gauge.

 

These 6 kits are available in 3 plantar plate sizes for the right and left sides.

 

INITIAL F – Lapidus

The plantar Lapidus plates have been designed to allow compression of the osteotomy site.

 

They feature a transfixing screw to achieve compression between the 1st metatarsal and the 1st cuneiform.

 

These plates have been designed for high adaptability, notably through the use of grade 2 titanium.

*The compression screws are not included in the IINITIAL F – Lapidus Kit (only the instrumentation is included); they are available separately in sterile single-unit packaging (S-box).

Key features of the INITIAL F – Lapidus kit.

  • Integrated transfixing screw within the plate for enhanced construct stability
  • Grade 2 titanium for optimized plate adaptability
  • Two blisters combined into a single single-use kit
  • A sterile, single-use, ready-to-use format suitable for emergency situations:
    • Reduced risk of contamination
    • No waiting time for restocking
    • Easy traceability thanks to detailed labeling
    • Reduced operative time and costs
    • Ergonomic format adapted to surgical sets

Our sterile solution: INITIAL F – MTP.

Arthrodesis of the first metatarsophalangeal (MTP I) joint is considered the gold standard treatment for advanced stages of hallux rigidus, the most common form of foot osteoarthritis. It aims to provide long-term pain relief while ensuring a return to weight-bearing.

In this context, INITIAL F – MTP is a single-use kit designed to address the challenges of standardization, logistical simplification, and infection risk control in forefoot surgery.

INITIAL F – MTP KIT

The INITIAL F – MTP kits consist of implants and instrumentation for performing arthrodesis of the first metatarsophalangeal joint (MTP). Each kit includes one plate size, screws (locked and non-locked), pins, a screwdriver, a length gauge, a handle for the guide gauge, a quick-release drill, and a threaded guide gauge.

 

8 kits available:

  • 3 standard plate sizes for the right and left sides
  • 1 narrow plate size for the right and left sides

To prepare the joint surface, single-use convex and concave burr kits (in 3 different diameters) are also offered.

 

INITIAL F – MTP

The plate design requires a medial approach, facilitating access to the posts positioned dorsomedially on the joint.
Additionally, the plate incorporates a transfixing screw passing across the MTP joint. These plates also feature an oblong post with a ramp to allow simple and controlled compression through the screw/plate interface.

The INITIAL F – MTP kit range includes:

  • 3 asymmetric standard plate sizes for the right and left sides

  • 1 asymmetric narrow plate size for the right and left sides

To prepare the joint surface, single-use convex and concave burr kits (in 3 different diameters) are also offered.

Key features of the INITIAL F – MTP kit.

  • Plate design for a medial approach
  • Transfixing screw ensuring compression
  • An oblong post with a ramp for simple and controlled compression through the screw/plate interface
  • Single-use sterile format, ready-to-use, adapted to operating room constraints:
    o Reduced risk of contamination
    o No restocking wait time
    o Easier traceability thanks to detailed labeling
    o Reduction of operative time and costs
    o Ergonomic format suitable for instrument sets

Certains produits ne sont pas disponibles sur tous les marchés. Pour vous permettre une navigation optimale merci de renseigner le pays où vous exercez.

Le site délivre des informations destinées uniquement à l’usage des professionnels de la santé. En cliquant sur Oui, vous confirmez que vous êtes professionnel de santé.
Ces informations ont pour intérêt de présenter la gamme de dispositifs médicaux de Newclip Technics. Ces produits doivent être manipulés et/ou implantés par des personnes formées, qualifiées et ayant pris connaissance de la notice d’utilisation. Le chirurgien reste responsable de son propre jugement professionnel et clinique avant toute utilisation de produits spécifiques sur un patient donné.